數據庫錯誤: [You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near '' at line 1]
SELECT * FROM `yh_models_set` WHERE channelId =

帕尔马队徽图片 卡利亚里vs亚特兰大

YH08 type 13C infrared spectrometer

YH08

相關批文:查詢

產品簡介: The YH08 13C infrared spectrometer is suitable for clinical medical diagnosis. The variation of 13C abundance in the 13C urea breath test sample is more than that of the bottom gas 13C abundance, DOB (%) is used to determine whether the subjects are infec

Medical equipment production enterprise license: Anhui food drug monitoring equipment production Xu 20160032
Medical equipment registration number: Anhui food drug supervision (quasi) 2014 2400117th



Communication connection between YH08 13C infrared spectrometer and computer:




YH08 13C infrared spectrometer interface of upper computer software:


<|@|>1) power supply: AC220V 50Hz, the maximum power rating of 250VA;
2) volume: length * width * high =540 mm x 404 mm x 345 mm;
3) weight: about 18Kg;
4) the core composition of the measurement system:
A. optical system: narrowband bandpass interference filter module + sapphire window film + optical lens
B. infrared light source: a steady state blackbody radiation source with a gold-plated mirror, working temperature at 950 degrees C
C. sample pool: Aluminum
D. detector: PbSe infrared photosensitive detector
E. signal shear: chopper circuit breaker
F. signal acquisition: band-pass filter + analog to digital converter + Fast Fourier transform software
G. temperature control system: PID control mode using electric heating element and Peltier refrigeration element
H. injection system: micro electromagnetic valve and precision step motor control cylinder type injection system;
5) operation control mode: software control, through the software on the user's computer and the special man-machine interface.
6) the way of information output: the special human-machine interface on the user's computer, and the user printer.
7) the main technical indicators:
A. repeatability: average value of less than 0.3 (conditions: measurement of a group containing 3%CO2, DOB (%) =0 standard gas sample 10 times);
The accuracy of B.: the standard error is less than 0.3 (conditions: measurement of a group containing 3%CO2, DOB (%) =2 standard gas sample 10 times);
The concentration range of CO2 in C. samples: 1 ~ 6%;
D. sample volume: 120mL/ bag;
E. sample measurement time: the time to measure a patient's sample (including the bottom gas sample and sample gas sample each bag) is about 3 minutes, and the CO2 concentration in the sample is different, which will make the measurement time different.
F. preheating time: about 30 minutes, the preheating time may be shortened and extended automatically due to the influence of ambient temperature.
8) electrical safety:
Anti electric shock grade: class I
Overvoltage category: Class II
Grade of pollution: Grade 2<|@|>

The YH08 13C infrared spectrometer is suitable for clinical medical diagnosis. The variation of 13C abundance in the 13C urea breath test sample is more than that of the bottom gas 13C abundance, DOB (%) is used to determine whether the subjects are infected with Helicobacter pylori (Hp).
YH08 13C infrared spectral instrument display:



<|@|>

 13C- urea breath test method

相關產品:

點擊數:1655 錄入時間:2018-02-09 08:52:37【打印此頁】【返回

?
公司地址:安徽省桐城市經濟開發區同祥北路8號  銷售熱線1:0556-6566669   銷售熱線2:0556-6566668  客服:0556-6567155  傳真:0556-6566668
版權所有:安徽養和醫療器械設備有限公司  皖ICP備18023964號  皖公網安備 34088102000494號  互聯網藥品交易服務資格證書:(皖)-非經營性-2018-0007
卡利亚里vs亚特兰大 九江股指期货配资 江西快3平台 广西福彩24选7走势图 浙江20选5开奖号 中国女子足球甲级联 股票指数投资策略可划分为 配股 理财排行榜收益最高 基金配资10倍 中国股神林园炒股秘籍